Wpływ środków dezynfekcyjnych na wymiary przestrzenne wycisków z mas alginatowych

ORYGINALNY ARTYKUŁ

Wpływ środków dezynfekcyjnych na wymiary przestrzenne wycisków z mas alginatowych

Marcin Szerszeń 1 , Michał Tyrajski 2 , Daniel Surowiecki 1 , Wojciech Poniewierski 2 , Bartłomiej Górski 3

1. Department of Prosthodontics, Faculty of Medicine and Dentistry, Medical University of Warsaw
2. Students’ Scientific Group, Department of Prosthodontics, Faculty of Medicine and Dentistry, Medical University of Warsaw
3. Department of Oral Surgery, Faculty of Medicine and Dentistry, Medical University of Warsaw

Opublikowany: 2020-02-19
DOI: 10.5604/01.3001.0013.8553
GICID: 01.3001.0013.8553
Dostępne wersje językowe: pl en
Wydanie: Postepy Hig Med Dosw 2020; 74 : 36-41

 

Abstrakt

Disinfection of dental impressions is a compulsory procedure performed in order to break the chain of infection. Disinfectants used for this purpose are divided into two large groups. These are ready-to-use disinfectants applied directly over the surface of the impression in the form of a spray and concentrates, which are used to prepare a solution in which the impressions are immersed for a specific period of time. This study aims to evaluate the influence of disinfectants on spatial dimensions of alginate mass impressions. Ninety cubic impressions were prepared using metal matrixes with external dimensions of 28 x 28 mm. Each impression was measured in two planes. The impressions were divided into three equinumerous sets of 30: Group I was disinfected with Zeta 7 Spray (n = 30), Group II was disinfected with Zeta 7 Solution (n = 30), and the control Group III (n = 30). The dimensions of the samples were measured in two planes after 24 (T1) and 120 (T2) hours. The obtained data was analysed statistically. The dimensions of the samples after 24 and 120 hours in the first group were significantly different from those of the control group and the differences were statistically significant (p <0.05). There was no statistically significant difference between the second and the control group after 24 and 120 hours. Ready-to-use disinfectants influence the dimensional stability of alginate-mass impressions. The time between taking the impression and preparation of the cast should be considered while choosing the disinfecting agent.

Przypisy

  • 1. Cervino G., Fiorillo L., Herford A., Laino L., Troiano G., AmorosoG., Crimi S., Matarese M., D’Amico C., Siniscalchi E., CicciuM.: Alginate materials and dental impression technique: Acurrent state of the art and application to dental practice. Mar.Drugs, 2019; 17: 18
    Google Scholar
  • 2. Choudhary S., Sivakumar I., Buzayan M.M., Choudhary P.: Dimensionalaccuracy of double poured casts obtained from extendedpour alginate impressions: An in vitro study. J. Int. Oral Health,2018; 10: 272–277
    Google Scholar
  • 3. Craig R.G.: Review of dental impression materials. Adv. Dent.Res., 1988; 2: 51–64
    Google Scholar
  • 4. Demajo K., Cassar V., Farrugia C., Millan-Sango D., Sammut C.,Valdramidis V., Camilleri J.: Effectiveness of disinfectants on antimicrobialand physical properties of dental impression materials.Int. J. Prosthodont., 2016; 29: 63–67
    Google Scholar
  • 5. Erbe C., Ruf S., Wostmann B., Balkenhol M.: Dimensional stabilityof contemporary irreversible hydrocolloids: Humidor versus wettissue storage. J. Prothet. Dent., 2012; 108: 114–122
    Google Scholar
  • 6. Faria A., Rodrigues R., Macedo A., Mattos M., Ribeiro R.: Accuracyof stone casts obtained by different impression materials. Braz. OralRes., 2008; 22: 293–298
    Google Scholar
  • 7. Gumuş H.O., Dincel M., Buyuk S.K., Kilinc H.I., Bilgin M.S., ZortukM.: The effect of pouring time on the dimensional stability of castsmade from conventional and extended-pour irreversible hydrocolloidsby 3D modelling, J. Dent. Sci., 2015; 10: 275–281
    Google Scholar
  • 8. Hiraguchi H., Kaketani M., Hirose H., Yoneyama T.: Effect of immersiondisinfection of alginate impressions in sodium hypochloritesolution on the dimensional changes of stone models. Dent. Mater.J., 2012; 31: 280–286
    Google Scholar
  • 9. Hiraguchi H., Nakagawa H., Wakashima M., Miyanaga K., SakaguchiS., Nishiyama M.: Effect of storage period of alginate impressionsfollowing spray with disinfectant solutions on the dimensional accuracyand deformation of stone models. Dent. Mater. J., 2005; 24: 36–42
    Google Scholar
  • 10. Kotsiomiti E., Tzialla A., Hatjivasiliou K.: Accuracy and stabilityof impression materials subjected to chemical disinfection – a literaturereview. J. Oral Rehab., 2008: 35; 291–299
    Google Scholar
  • 11. Martin N., Martin M.V., Jedynakiewicz N.M.: The dimensionalstability of dental impression materials following immersion in disinfectingsolutions. Dent. Mater., 2007; 23: 760–768
    Google Scholar
  • 12. Michalakis K., Stratos A., Hirayama H., Pissiotis A., Touloumi F.: Delayedsetting and hygroscopic linear expansion of three gypsum productsused for cast articulation. J. Prosthet. Dent., 2009; 102: 313–318
    Google Scholar
  • 13. Muzaffar D., Ahsan S.H., Afaq A.: Dimensional changes in alginateimpression during immersion in a disinfectant solution. J. PakistanMed. Assoc., 2011; 61: 756–759
    Google Scholar
  • 14. Muzaffar D., Braden M., Parker S., Patel M.: The effect of disinfectingsolutions on the dimensional stability of dental alginateimpression materials. Dent. Mater., 2012; 28: 749–755
    Google Scholar
  • 15. Nassar U., Aziz T., Flores-Mir C.: Dimensional stability of irreversiblehydrocolloid impression materials as a function of pouringtime: A systematic review. J. Prosthet. Dent., 2011; 106: 126–133
    Google Scholar
  • 16. Peutzfeldt A., Asmussen E.: Effect of disinfecting solutions onaccuracy of alginate and elastomeric impressions. Scand. J. OralRes., 1989; 97: 470–475
    Google Scholar
  • 17. Rodrigues S., Augusto C., Leitune V., Samuel S., Collares F.: Influenceof delayed pouring on irreversible hydrocolloid properties.Braz. Oral. Res., 2012; 26: 404–409
    Google Scholar
  • 18. Sweeney W., Taylor D.: Dimensional changes in dental stone andplaster. J. Dent. Res., 1950; 29: 749–755
    Google Scholar
  • 19. Szerszen M., Surowiecki D., Tyrajski M.: Influence of storageconditions of alginate mass impressions on their spatial dimensions.Prosthodontics, 2018; 68: 406–414
    Google Scholar

Pełna treść artykułu

Skip to content